Specifications

XR Series Installation Instructions 53
RS485 light not flashing: Verify the RS485 terminal is being used and check
communications wiring at the indicator.
Verify that data is being sent to the XR from the
indicator and that the data string contains numeric
characters.
20mA light not flashing: Verify the 20mA terminal is being used and check
communications wiring at the indicator.
Verify that data is being sent to the XR from the
indicator and that the data string contains numeric
characters.
Make sure the correct mode (ACTIVE or PASSIVE) is
selected on the Controller board (SW10).
RADIO light not flashing: Check that the radio module is properly installed.
Ensure that the internal antenna cable is connected
to the radio module and the external antenna.
No data is being sent from the ScaleLink radio
connected to the scale indicator.
COM light not flashing: XR
2000 only
Verify the correct terminal (RS 232, 422/485, 20 mA)
is being used and check communications wiring at
the indicator.
Verify that the communications “Input Select” jumper
is set to the proper communication mode (RS 232,
422/485, 20 mA).
If the radio module is being used, also see Probable
Solutions for “Radio light not flashing”
Verify that data is being sent to the XR from the
indicator and that the data string contains numeric
characters.