User`s manual
WP-234 Printer User’s Manual 17
The sample list above shows the current baud rate
is 1200. To accept this, press OK (right side) or
view the next baud rate value by pressing NEXT
(left side). Press OK when the baud rate you want
is displayed.
Choose from these baud rates;
300, 600, 1200, 2400, 4800, 9600, or 19200
DATA BITS is the next parameter. Choose the
data bit value the same way baud rate was
chosen. Choices are 7 or 8 data bits. Parity will
appear next only if you choose 7 data bits.
If you choose 7 data bits you can select EVEN or
ODD parity. If you choose 8 data bits parity defaults
to NONE.
STOP BITS is the next parameter. Choose 1 or 2
stop bits.
HANDSHAKE is the next parameter. Choose from
the following settings:
BUSY-LINE
BUSY-BUFFER
XON/XOFF-LINE
XON/XOFF-BUFFER
NONE
COLUMNS is the next parameter. Select the
number of characters per line (columns) for this
parameter. The choices you have are 24, 32, or 40.
Below are samples of each:
INVERT is the next parameter. Choose YES if you
want inverted text (upside down) or NO if you want
non-inverted text (right side up) in your printouts.
Below is an example of inverted text.
Baud Rate
Data Bits
Stop Bits
Handshake
Handshake is used
for serial interface
only.
Invert
Cols
Parity