Model 1310 Truck Scale In/Out Application User’s Manual
Ethernet 10/100 SMTP Option
If your 1310 has the optional Ethernet 10/100 SMTP card installed, your
system can be configured to send you an email informing you of system
errors as they occur. Follow the steps below to set up your 1310 for auto-
notification.
1. Open SimPoser.
2. Open the standard truck IN/OUT application file.
3. Click on the CONFIG button.
4. Click on the Parameters tab.
5. Click on the Diagnostics button.
6. Enable Email under Alarm Levels.
7. Click OK.
8. Click on the Network tab.
9. Choose Ethernet IT from the Network Type list.
10. Click on Enable.
11. Configure the IP, SUBNET MASK, GATEWAY and SMTP IP as shown
in the example below:
12. Click File>Save.
13. Download to your 1310.
14. To configure the TO and FROM email addresses, press and hold the
ESC key for five seconds on the 1310. Enter the password 411. A
prompt will appear for the From address then the To address, as you fill
in the information. Exit the menu and save your changes.
Email data will display system
overload and underload counts
only.