User`s manual
20
Model 1310 Truck Scale In/Out Application User’s Manual
MODM Appears only if modem is enabled by a SimPoser
program. The display will show Port #, Status (see list at
left), User configuration information.
TRAFF Press this soft key to see the System Counter Menu.
This shows you the traffic, overload, and underload
counter values. See example below.
If the scale experiences a load exceeding 105% of
capacity, an overload event is logged. Press the OVER
soft key to see the log of overloads. Example below.
Press the PREV or NEXT soft keys to scroll through the
list of overload event times and dates. Press the
CLEAR soft key to clear the displayed event.
If the scale experiences a negative weight exceeding
105% of capacity, an underload event is logged. Ex-
ample below.
Press the PREV or NEXT soft keys to scroll through the
list of overload event times and dates. Press the
CLEAR soft key to clear the displayed event.
The traffic counter increments when weight exceeds the
configured trigger point (% of scale capacity). (See the
Service Manual for configuration information.) For the
next weightment to increment the counter, the weight
must fall below the configured re-arm point (% of scale
capacity).
Modem status list:
1 = initialize
2 = set auto answer
3 = set user config
4 = port ready
5 = dialing
6 = error
7 = connected
8 = disconnected
9 = initialize 2