Error Messages
Error Messages from
SensorComm
TM
You may see the error messages listed in the table below. Also listed is a
description of the error and possible causes. These may help with servicing.
Error messages will appear in the upper right corner of the display window
as shown in the example of error message #8 shown below.
Error # Error Description of Error Possible Cause
1 Communications error SensorComm not responding -Cable
-SensorComm hardware failure
-1310 hardware falure
2 Power fault +Vin, +EXC, or -EXC has fallen out -Power supply failure
of tolerance. Voltage ±5%. -Cable
3 A to D overrange More than +5mV/V has been applied -Cable
to the A to D converter -Weight sensor failure
4 A to D underrange Less than -5mV/V has been applied -Cable
to the A to D converter -Weight sensor failure
5 A to D Initialization A to D converter not responding -Component failure
failure -Power supply problems
6 Weight sensor overrange The weight sensor output has -Abuse of scale
exceeded the configured amount. -Weight sensor failure
7 Weight sensor deadload The output of the weight sensor is -Gauging problem on the weight
shift warning greater than a configurable percent of sensorf
capacity since calibration -Mechanical issuse with the scale
8 Weight sensor deadload The output of the weight sensor has -Gauging problem on the weight
shift error increased more than a configurable sensor
percent of capacity since calibration -Mechanical issuse with the scale
9 Weight sensor stability The output of 1 or more weight -Mechanical issuse with the scale
sensor is not in the same range as -Weight sensor problem
the rest of the scale.
All error messages below which mention components
are referring to components within the SensorComm product.
Error Message from
the Ghost Feature
You may see an error message when the Ghost feature is enabled.
The display at left tells you the
Ghost option is functioning and that
Cell X has failed.