User`s manual
WP-233 Printer User’s Manual36
Selectable Column
Width
Codes 29, 30, 31
Printable
Characters
NOTE: (ASCII
characters from Hex
80 to FF are
unsupported and
will cause problems
if you attempt to
print them.)
Printer Escape
Command Code
Definitions
The printer powers up in the column mode last
selected by configuration. You can change the
column width by sending the appropriate control
code from the list below:
Control code 29 - 24 columns
Control code 30 - 32 columns
Control code 31 - 40 columns
You can send the control code at any point on a
line before the buffer becomes filled. You cannot
change column widths on the same line.
The RS-232 serial version can produce all ASCII
characters from hex 20 through hex 7D (decimal
32 through 125). Here’s what they look like:
Note the last two codes of the usual ASCII charac-
ter set are not supported. Instead, if CHR$(126),
which corresponds to hexadecimal 7E, is received
by the printer, it will print the character defined in its
RAM (Random Access Memory). The section on
USER Programmable Character describes how
this RAM can be loaded with any 6 x 8 pattern.
Command Print formatted data
<ESC> 0 HH:MM 24 hour format
<ESC> 1 HH:MM_?M 12 hour format with
AM or
PM
<ESC> 2 MM/DD/YY month/day/year
<ESC> 3 DD-MM-YY day-month-year/numeric
month
<ESC> 4 DD-MON-YY day-month-year with 3
letter abbreviation of the
month
<ESC> 5 DOW day of week abbreviation
<ESC> 6 currently configured format
<ESC> 9 XXXX current sequence
number