12.3 Inaccurate Weight Readings
12.3 Inaccurate Weight Readings
First: Visually Inspect The Scale System for apparent problems and improper
installation:
1. Check each cable, from source to indicator, for stress, cuts, breaks, or
abrasions.
2. Unplug and reconnect each connector at the indicator to verify that it is tight
and making good contact.
3. Check the hitch Weigh Bar
®
and verify that mounting bolts are tight and the
hitch is not binding.
4. Check between the wheels and frame of the implement for mud and debris
that might restrict Weigh Bar
®
movement.
5. Check betwccn supporting structure and weighing structure for debris that
might restrict Weigh Bar
®
movement.
6. Make sure the supporting structure and weighing structure do not touch each
other at any point except at the Weigh Bars
®
.
Next: Compare Weight Readings for All Weigh Bars
®
:
Position a person or heavy object on the platform above each Weigh Bar
®
, one bar at
a time, and compare weight readings for the same person or same object.
For each weighing, the weight itself will be off-center, favoring a single Weigh Bar
®
;
therefore, none of the readings will be accurate.
However, your readings obtained by weighing the same person or object above each
Weigh Bar
®
should be nearly identical to each other. A single Weigh Bar
®
reading that
is significantly different from the others is probably defective.
12.4 Measuring Supply Battery Voltage
To check battery voltage:
1. Press and hold MENU for three beeps.
SET.PAS is displayed.
2. Enter 111. Press SELECT…
VOLTS is displayed.
3. Press SELECT to display incoming battery voltage.
4. Press SELECT to return to VOLTS .
5. Press GROSS to return to gross weighing mode.