Instruction manual
Model 1040/XL User Instructions 57
10.1 Access the Test Menu
10.1.6 Inputs test
26. Use this to test the inputs in the 1040. From the INPUTS display, press the
SELECT key…
IN.1 is displayed.
27. Press the SELECT key…
OPEN or CLOSED is displayed.
28. Press the SELECT key…
IN.1 is displayed.
29. Press the MENU key…
IN.2 is displayed.
30. Press the SELECT key…
OPEN or CLOSED is displayed.
31. Press the SELECT key…
IN.2 is displayed.
32. Repeat steps 29-31 until all inputs are checked.
33a. Press the GROSS key to return to INPUTS and then press MENU to advance
to next menu item…
RELAY is displayed
OR
33b. Press the GROSS key to return to gross weighing mode.
10.1.7 Relay test
34. Use this to test the alarm light relay. From RELAY display, press the SELECT
key…
ON/OFF is displayed. While this is displayed the alarm light should flash
two times per second.
35. Press the SELECT key…
RELAY is displayed.
36a. Press the GROSS key to return to gross weighing mode
OR
36b. Press MENU to advance to next menu item…
SOFT is displayed.