Instruction manual

54 Model 1040/XL User Instructions
Indicator Diagnostics
10 Indicator Diagnostics
The test mode is used to test various functions of the 1040 Indicator. The test menu is
shown in Figure 10. Instructions for using the test menu are found below.
Figure 10.1 Test Menu (password 111)
You can test the following functions of the indicator with this menu:
VOLTS Monitor the input voltage of the indicator
LCD Perform a test of the LCD display
KEYPAD Peform a key test
A/D Test the Analog to Digital function
SERIAL Check serial ports 1 and 2
INPUTS Check the 7 TTL inputs (INPUT.1 is XM64, SPEED is for Self Adjusting
Time mode.
RELAY Check the alarm relay
SOFT Verify the software verision of the indicator
Use the MENU and SELECT keys to navigate the menu shown in Figure 10.1 Step by
step instructions appear below.
10.1 Access the Test Menu
1. Press and hold the MENU key for 3 beeps (about 3 seconds). Release the
key…
SET.PAS is displayed.
2. Key in the password, 111, and press the SELECT key…
VOLTS is displayed.
GROSS
SET.PAS
LCD KEYPAD A/D SERIAL
RELAY
INPUTS
SOFT
Display
segment
test
Press
any key
View int.
raw
counts
Open
or
Closed
Open
or
Closed
Open
or
Closed
Open
or
Closed
Open
or
Closed
Open
or
Closed
Open
or
Closed
Loop/NoLoop
Part No.-
XXXXX-
Dash No.-
-XXXX
Rev-
REV-
ON/OFF
IN.1 IN.2 IN.3 IN.4 INPUT.1 INPUT.2 SPEEDView input
voltage
VOLTS
Press and hold
for 3 beeps
MENU
Key in 111 and
press
SELECT