Instruction manual

42 Model 1040/XL User Instructions
Other Operations
9.3 Mix Timer Operation
The Model 1040 has a mix timer feature that can be configured for one of two methods;
Time mix or Self Adjust Time.
9.3.1 Time Mix
After a batch is loaded, you can activate a timer, or the Model 1040 can be configured
to activate the timer automatically.
Configure this under user’s menu-TIMER/TIME. MAX time = 5959, or 59 minutes and
59 seconds. Invalid data entry will be displayed as CAN’T. You need to clear the data
and re-enter it as a valid time.
1. From the gross mode, enter in timer in minutes/seconds…
MMSS is displayed
2. Press the TIMER key…
TC MM:SS is displayed for three seconds, and then starts counting
down. When the end of the timer cycle is reached the red alarm light is
lit.
3. Press the GROSS key to disable and return to the Gross mode.
To view the current timer setting:
1. From Gross mode, press TIMER
TC MM:SS is displayed (MM:SS is the last entered value) for three
seconds, then timer starts to count down.
2. Press GROSS to return to the gross mode.
Self Adjust Time
This option requires that a magnetic proximity sensor be installed onto the mixer to
provide speed inputs to the Model 1040 every time a full rotation is detected. Overall
operation is the same as standard time, but will adjust depending on speed.
The target speed must have been calibrated prior to correct operation.
1. Press the TIMER key…
SPD.CAL is shown while the speed of the mixer is calculated. Then, the
new adjusted time is shown; ST:MM:SS and the timer will count down.
The operation from this point is the same as standard Time Mix.