Specifications
01/02 Rev. 2.13-02 MANUAL Attachment, Setup, Service, Page 6
TCS
6
6
7
8
3
2
1
Setting the stacker
Setting the material width
1. Measure the material width if unknown.
2. Unscrew the two thumb screws (6) on
the stacker.
3. Push the side part until its right-hand
edge corresponds to the measured
material width on the scale (7). Width
set in the illustration: 52 mm.
Odd dimensions are given in the lower
half of the scale, even dimensions in the
upper half.
4. Tighten the thumb screws.
Setting the material support
Push the material support (8) up to the
stop plate.
Setting the pusher
1. Open the plexiglass cover.
2. Unscrew the thumb screw (1).
3. Push the right-hand pusher (2) about
1 cm to the left. Turn the spacing lever
until it is at right-angles to the edge (3).
Push the pusher to the right again up to
the spacing lever.
4. Tighten the thumb screw.
5. Turn the spacing lever back (parallel to
the edge).
6. Close the plexiglass cover