Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
77
9034 Use min 16MB RAM
Status The printer has not enough RAM. The applied firmware version needs at
least 16 MB RAM for faultless operation.
Measure
Extend the pritners RAM.
9035 No printpr. stop
Status This status message may appear during the loading of new firmware onto
the H8 (64 Bit) or onto boards, which are connected to the H8 (e.g.
Applikator Interface).
Measure
Switch the printer off and on again and retry the firmware loading.
9036 DMA switch off
Status An error status of the DMA controler was discovered, which can only be
cured by switching off the device.
A reset is not sufficient!
Measure
Switch the device off and on again.
9100-9119 Messages during firmware update
9100 Invalid format
Status Occurs during a download. The sent data is faulty, e. g. regarding an
invalid data format
invalid check sum
invalid address
invalid record type
Measure
Switch printer off and on again. Check the download data.
9101 Invalid Header
Status Occurs during a download. The sent files have a format error in the header.
Measure
Switch printer off and on again. Check the download data.
9102 Inv.Board Rev.
Status Occurs during a firmware download. The sent firmware does not match the
version of the CPU board.
Measure
Switch printer off and on again. Check the download data.
9103 Inval. firmware
Status Occurs during a firmware download. The sent firmware does not match the
installed CPU board.
Measure
Switch printer off and on again. Check the firmware file.