Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
76
9022 No network link
Status This message can only occur, if the Ethernet address assign is set to
DHCP. The cause is nearly always a badly connected network connector.
Measure
Check, if the network connector is plugged in properly.
9023 Filename: Functionname() Line: xxx
Status This status message indicates a software error. The error source is located
in the source file “Filename” in function “Functionname()” in line xxx.
Measure
Switch device off and on again.
If the error occurs repeatedly:
Contact the manufacturer.
When doing so, it is important to be able to reproduce the error. Gather the
following informations before calling the technical support of the
manufacturer:
-- Displayed information about the error source
-- Label layout, logfiles, etc. as described in chapter Unspecific errors
9024 Not possible !
Status Detecting the material length (a function, which is normally used with MLI)
is not possible, because a printjob is currently processed.
Measure
Retry as soon as the printjob is processed.
9030 Log file:CF full
Status An attempt to store data on the memory card was not successful, because
of a full card.
Measure
Clear some storage space on the memory card, or
Insert an empty memory card.
9031 Log file: nnnn
Status File access error. nnnn = error code of the operating system.
Measure
Repeat the operation, which led to this message. If it comes to this
message repeatedly, send a message to the Technical Support, including
the error code.
9032 EP file log stop
Status Internal error during Easy-Plug file logging (SPECIAL PARAMETER >
EasyPl. file log).
Measure
Repeat operation. If the error occurs repeatedly: switch off the file logging.
Use parameter SPECIAL PARAMETER > EasyPl. file log only for error analysis
purposes. Using the parameter in continous operation can cause error
messages, which are hard to understand.