9014 Motor voltage
Status Faulty 45 V motor supply voltage. A possible cause is a short circuit, that is
the printhead is defective.
Measure
Replace the printhead
9015 Network init.
Status Error during the network initialization.
Measure
Contact your network administrator.
9016 DHCP Failed
Status DHCP failed. This may happen, if parameter INTERF. PARAM. >
ETHERNET PARAM. > IP Adressassign is set to DHCP, but no IP-address can be
drawn.
Measure
Contact your network administrator.
9017 RTC read failed
Status Error, while trying to read the realtime clock (RTC). Happens, if an Easy-
Plug command to read out the RTC is sent, but no RTC is built in.
Measure
Check, if the printer is supplied with a RTC. To do so, print a status
printout.
See parameter INFO PRINTOUT > Printer status
You find the actual date on the printout, below the header „Systemversion“,
if a RTC is installed.
Check, if the error occurs repeatedly or sometimes.
If it occurs repeatedly:
AP 5.4: replace the CPU board.
64-xx / ALX 92x / DPM / PEM: Replace the RTC. If the error still occurs,
replace the CPU board.
If the error occurs sometimes, please refer to the notes in section General
software errors
.
9018 #!CA wrong Pos.
Status The #!CA command is placed at an inadmissible position – the Easy-Plug
interpreter can not proceed the command at this position (e. .g during the
loading of files onto a memory card).
Measure
Call the #!CA command at an admissible position.
9020 Param. ID wrong
Status A not existing parameter ID was used.
Measure
Correct the parameter ID.