8900 Codablock columns
Status Bar code Codablock: illegal number of columns.
Measure
Correct number of columns.
8901 Codablock rows
Status Bar code Codablock: illegal number of rows.
Measure
Correct number of rows.
8902 Codablock softw.
Status Bar code Codablock: software error.
Measure
8903 Codablock infogr
Status Bar code Codablock: info not in line.
Measure
8950 Logo open
Status Failure when attempting to read a logo, which has previously been copied
on RAM disk or on memory card (thus using Easy Plug command #DK).
Measure
Repeat loading the logo via #DK command.
In cases of continuous occurence of this error, please contact the technical
support.
8951 File format
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.
8952 Not installed
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.
9000 Wrong errornum
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.