Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
70
8803 Maxicode Class
Status Maxicode: faulty class code.
Measure
Correct class code.
8804 Maxi. Sec. mess.
Status Maxicode: secondary message has an illegal length.
Measure
Correct length of secondary message.
8805 Maxicode Country
Status Maxicode: faulty country code.
Measure
Correct country code.
8830 Cod49 Datalength
Status The user data string is too long. Not all characters can be coded in the bar
code. The bar code is not printed.
Measure Shorten the data string.
8031 Cod49 wrong data
Status The data string contains wrong characters. The bar code is not printed.
Measure Correct the content of the data string.
8850 Unknown filetype
Graphic files with the extention declared in the Easy Plug command #YG
are not supported.
Measure
Transform the graphics file into another file format or use another graphic in
a supported format. Check, if the spelling of the file extention is correct.
8851 Graphic open
Status The graphics file declared in the Easy Plug #YG command cannot be found
on the compactflash card. Possible reasons are:
•
Path and/or designation of the graphics file stored on the compactflash card
doesn´t match the path and/or designation declared by the #YG command.
•
The file is not available on the compactflash card.
Measure
Check if the spelling of the graphics file is the same both in the #YG
command and on the compactflash card.