Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
68
8406 PDF417 Details
Status Bar code PDF417: incorrect details.
Measure
Alter details.
8407 PDF417 Coding
Status Bar code PDF417: coding error.
Measure
Switch printer off and then back on again after thirty seconds.
Acknowledge by pressing the Online button.
8500 Code 25Int len.
Status Bar code Code 25 Interleaved: input line too long.
Measure
Shorten input line.
8501 Postcode length
Status Bar code postcode: illegal data length.
Measure
Check length of the transmitted data and set it to the permitted length.
8600 EAN Length
Status Bar code EAN: illegal data length.
Measure
Check length of the transmitted data and set it to the permitted length.
8601 UPCE Numbers sys.
Status Error: First data character of the transmitted data is not 0 or 1.
Measure
Alter first data character to 0 or 1.
8700 IDM Data with 0
Status Bar code IDM: data may not contain 0x0.
Measure
Correct data.
8701 IDM Data length
Status Bar code IDM: Illegal length of data string.
Measure
Check length of the transmitted data and bring it to the permitted length.
8702 IDM Coding
Status Bar code IDM: coding error.
Measure