Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
67
8309 Module range
Status Maximum range of the bar code module exceeded.
Measure
Reduce module range.
8310 Bar code element
Status Bar code element exceeds the maximum permitted size of 253 dots
(21 mm).
Measure
Reduce size of the bar code element.
8311 Barcode table
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.
8400 PDF417 ECC
Status Bar code PDF417: incorrect ECC level (Error Correction Level).
Measure
Alter ECC level.
8401 PDF417 Lines
Status Bar code PDF417: illegal number of lines.
Measure
Alter number of lines.
8402 PDF417 Columns
Status Bar code PDF417: illegal number of columns.
Measure
Alter number of columns.
8403 PDF417 Style
Status Bar code PDF417: incorrect style.
Measure
Alter style.
8404 PDF417 Command
Status Bar code PDF417: incorrect command.
Measure
Acknowledge by pressing the on-line button.
Check and alter commands.
8405 PDF417 Size
Status Bar code PDF417: incorrect size.
Measure
Alter size.