Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
66
8301 Bar code data
Status Incorrect bar code data. The bar code data is not permitted for the selected
bar code type.
Measure
Use data permitted for the bar code type.
8302 Barcode checksum
Status Error during calculation of the bar code check sum.
Measure
Check transmitted data.
If the error continues to occur please contact the manufacturer. Send the
transmitted Easy Plug data.
8303 Bar code sample
Status Error during calculation of the bar code sample.
Measure
Check whether the transmitted data is permitted for the bar code type; if
necessary alter the data.
8304 Bar c. plain-copy
Status Error during integration of the plain-copy line in the bar code sample.
Measure
Check whether the transmitted data is permitted for the bar code type; if
necessary alter the data.
8305 Bar code print
Status Error during calculation of the bar code print image.
Measure
Acknowledge by pressing the Online button.
Measure
Check whether the transmitted data is permitted for the bar code type; if
necessary alter the data.
8306 Plain-copy len.
Status Illegal: bar code plain-copy line has more than 300 characters.
Measure
Reduce line length.
8307 Readline dist.
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.
8308 Bar code ratio
Status Illegal bar code ratio.
Measure
Select another ratio.