Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
61
6030 Param. checksum
Status Wrong parameter checksum.
Measure
None. The message is merely informativ.
6031 New Parameters
Status By loading a new firmware version, some new parameters have been
added to the parameter menu.
Measure
None. The message is merely informativ.
6101 No sensor found
Status Error during the running of the "Sensor Test" service function.
Measure
Acknowledge by pressing the online button.
Contact service technician.
6200 Filesystem regis
Status General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors
.
6201 File sys. format
Status Error during formatting of the RAM disk or the memory card.
Measure
Switch printer off and then back on again after thirty seconds. If the error
message continues to appear, please contact the manufacturer.
6202 Drive open
Status Accessing the memory card failed.
Measure
Format the memory card using the PC card drive. Try again to write onto
the card.
Try another memory card.
6203 Filesystem close
Status Accessing the memory card failed.
Measure
Format the memory card using the PC card drive. Try again to write onto
the card.
Try another memory card.
6204 Disk directory
Status Work directory cannot be opened.
Measure
Acknowledge by pressing the Online button.
Check designation existence of the work directory.