5525 Tag read err
Status The plausibility test of the read data failed. Possible reasons are:
The tag is out of reach of the antenna, after it has already been recognized.
Noise signals avoid the transmission.
Measure
Check the system for the mentioned error causes and correct them.
5526 Tag select first
Status A read or write command was given without selecting the transponder at
first.
Measure
Add a select command before using the read/write command.
5527 Tag RF comm err
Status Transponder and reader are unable to communicate. Possible reasons are:
More than one transponder is within reach of the antenna.
No transponder is within reach of the antenna.
Measure
Check the label material feeding; eventually remove paper jam.
5528 EEPROM failure
Status
The reader cannot write on the transponder EEPROM.
A faulty checksum was detected before writing on the EEPROM.
Measure
Repeat the writing attempt.
Try another transponder
5529 Parameter range
Status Faulty address. Transponders of the same type may have memory ranges
of different sizes; according to this, the admissible addresses differ too.
The fault occurs, if a block address targets beyond the address range of the
transponder.
Measure
Change the address.
Use a transponder with a wider address range.
5530 Unknown CMD
Status The reader doesn´t support the used command.
Measure
Change or replace the command.
5531 Protocol length
Status General software error
Measure Please read the notes in section General software errors
.