Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
53
5204 Appl. Starterror
Status The device received another start signal during printing/applying a label.
Precondition: Parameter APPLICATOR PARA > Start error stop or
DP INTERFACE > Start error stop is set to On.
Measure
Check the labelling procedure; increase the product distance.
Set parameter Start error stop to Off.
5205 Applicator gen.
Status General software error
Measure Please read the notes in section General software errors
.
5206 Applicator resp.
Status Communication with the AI exceeded a given time frame.
Measure
Switch the printer off and on again after half a minute. If the error still
occurs after several trys, please contact our technical support.
5207 Appl. driver 1
Status Shortcut or overheat at power output 1 of the AI.
Measure
Check the connections.
5208 Appl. driver 2
Status Shortcut or overheat at power output 2 of the AI.
Measure
Check the connections.
5209 Appl. driver 3
Status Shortcut or overheat at power output 3 of the AI.
Measure
Check the connections.
5210 Appl. driver 4
Status Shortcut or overheat at power output 4 of the AI.
Measure
Check the connections.
5212 Vx.x for AI rec
Status The required AI firmware (version x.x) is not installed.
Measure If the installed AI firmware is older than the required version:
Acknowledge message. Load AI firmware version x.x.
If the installed AI firmware is newer than the required version:
The message is acknowledged automaticallly.