Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
52
5131 PSU communicat.
Power supply communication
(64-xx / DPM / PEM / ALX 92x / PM 3000 only)
Status A fault occured during communication with the power supply via I
2
C bus.
Measure
Switch the printer off and after 30 seconds on again. If the message
continues to appear, contact the manufacturer.
5150 No USI interface
Status (DPM / PEM / ALX 92x only)
This error appears, if no USI is detected while the printer is powering up.
Measure
Check, if the USI is defective or not built in.
5151 Applic. interf.
Applicator interface
Status (DPM / PEM / ALX 92x only)
Neither Applicator Interface (AI), nor USI are connected to the device.
Measure
Connect a USI or AI to the device.
5200 Home position
Status The applicator did not reach its home position within the given time frame.
Possible causes:
The applicator is jammed
Applicators driven by compressed air: The air supply may be interrupted or
switched off
Cable not connected properly
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
May the applicator move unhindered? – remove any obstacles.
5201 Touch down
Status The applicator did not reach its touch down position within the given time
frame.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
May the applicator move unhindered? – remove any obstacles.
5203 Touch down sens.
Status The touchdown sensor(s) was/were already triggered before the
application.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.