Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
51
Byte 2: xxxxxxxx
x x
7 6 5 4 3 2 1 0
Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.
Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.
not used
not used
not used
Temperature sensor defective:
The measurement at the A/D-
converter leads to a temperature
below –20°C or over +170°C. All
outputs except the logic supply are
switched off.
Operation time counter:
Data are not consistent in connection
with the operation time counter.
EEPROM error:
Data content of the EEPROM is not
consistent.
Byte 3: xxxxxxxx
x x
(can only be 00H or F0H)
7 6 5 4 3 2 1 0
not used
not used
not used
not used
not used
not used
not used
I
2
C transfer error
Byte 4: xxxxxxxx (is not being used yet)
Example: 0000F020 means: "EEPROM error" and "Fan defective".