Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
47
5061 Dispenser motor
Status The output stage board for the dispenser motor is not present or defective.
Measure
Press the Online button to acknowledge.
Check the output stage board for the dispenser motor and eventually
exchange it.
5062 Disp. lift motor
Status The output stage board for the dispenser lift motor is not present or
defective.
Measure
Press the Online button to acknowledge.
Check the output stage board for the dispenser lift motor and eventually
exchange it.
5063 Press roll
Status Dispenser version: press roll is not closed.
Measure
Close the press roll.
5064 Backing paper
Status Happens with dispenser version printers: Shows up, when the diameter of
the rewinded backing paper roll has become too large.
Measure
Clear the rewinding mandrel.
Press the Online button to acknowledge.
5100 No H8 response
Status Communication fault with H8 processor (occurs only at devices with Gen. 2
electronics).
Measure
Acknowledge by pressing the Online button.
Switch device off and on again.
If the message continues to appear:
Contact service technician.
Instructions for service technicians:
The error can occur in connection with the exchange of the CPU board of
an ALX 92x machine.
Acknowledge error, set all sensors, restart.
If the error message still appears: Reload firmware and/or carry out a
forced bootloader start with "Clear params".
If the error continues to appear: send CPU board with a fault description to
the manufacturer.