Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
46
5056 Infeed 2 empty
Status (TT4 only) While initializing, TT4 reports no material in infeed 1.
Precondition for this status message is, that parameter
SYSTEM PARAMETERS > w/wo magazine is set to „with“.
Measure
Check, if the material in infeed 1 is loaded correctly, respectively if it´s
loaded at all. Acknowledge by pressing the Online button.
5057 Infeed 3 empty
Status (TT4 only) While initializing, TT4 reports no material in infeed 1.
Precondition for this status message is, that parameter
SYSTEM PARAMETERS > w/wo magazine is set to „with“.
Measure
Check, if the material in infeed 1 is loaded correctly, respectively if it´s
loaded at all. Acknowledge by pressing the Online button.
5058 Infeed 4 empty
Status (TT4 only) While initializing, TT4 reports no material in infeed 1.
Precondition for this status message is, that parameter
SYSTEM PARAMETERS > w/wo magazine is set to „with“.
Measure
Check, if the material in infeed 1 is loaded correctly, respectively if it´s
loaded at all. Acknowledge by pressing the Online button.
5059 Stacker full
Status (AP 7.t only) This message can only appear if a TCS is applied as
peripheral device. It indicates, that the stacker is full or the protection cover
is opened.
Measure
Empty stacker
Close cover
If the message appears in spite of a closed cover and an emptied stacker,
check the function of lid switch and microswitch.
5060 Stacker full
Status This message can only appear if a TCS is applied as peripheral device. It
indicates, that the stacker is full or the protection cover is opened.
Measure
Empty stacker
Close cover
If the message appears in spite of a closed cover and an emptied stacker,
check the function of lid switch and microswitch.