Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
44
5025 I2C Polling xx
Status Polling error during communication via the I
2
C bus with the device xx (see
Tab. 4 on page 38).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5026 Motorprotect CPU
Status (AP x.x only) The motor driver board (output stage board) is overheated or
defective.
Measure
Switch printer off and then back on again after 30 sec.
If the error message continues to appear:
Replace the motordriver board.
5028 PS overheat
(AP x.x only)
Status The temperature inside of the power supply exceeded the admissible
range.
Measure
Let the power suppy cool down for some minutes.
5029 I2C checksum xx
Status During I
2
C communication with device xx occured a checksum error.
xx = I
2
C device number (see Tab. 4 on page 38).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.