Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
38
Status # Text Missing output stage for the following
device:
5005 Knife-fault Cutter motor
5006 Head-fault Print head liftmotor
5008 Ribbon end Ribbon motor
Tab. 2 Those status messages indicate, that the device is not connected to the I
2
C bus.
Third may follow one of the status messages listed below:
Status # Text
5020 I2C Timeout xx
5021 I2C Conf. xx
5022 I2C Busy xx
5023 I2C LAB xx
5024 I2C BER xx
5025 I2C Polling xx
Tab. 3 Status messages, which help to further locate the I
2
C bus error. xx = Device ID of
the concerned device (see 0)
# Device 64-xx DPM / PEM ALX 92x AP 5.4 AP 7.t
0 CPU X X X X X
1 Feed motor X X X X
2 Foil motor X X X
3 Printhead motor X X X X
4 Peripheral motor X X
5 Dispenser motor X
5 Rewinder motor X
8 Rewinder (internal) X X
12 USI board X X X
13 (Reserved)
15 I/O board X X X X X
16 EEPROM X X X X X
17 Realtime-clock X X X X X
18 Power supply X
1)
X X
Tab. 4 Assignment of device IDs as used in status messages related to the I
2
C bus.
1) Only with the power supply types HME and ME 500.