Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
34
2005 Exp. comma pos.
Status Unexpected comma in the expression.
Measure
Check the syntax of the expression regarding commas.
2006 Exp.functionname
Status A wrong function name is used in the expression.
Measure
Check, if the function names used in the expression are spelled correctly
and if the functions exist. Change the function name.
2007 Exp.fct.paratype
Status A wrong parameter type in an expression was detected.
Example: SubStr(“Text”,o,”A”) would provoke this message, because “A” is
not a number.
Measure
Check the expressions. Correct the wrong expression.
2008 Exp.fct.paraCnt
Status Wrong number of function parameters in the expression.
Measure
Check the expressions. Correct the wrong expression.
2009 Exp. name wrong
Status A not defined variable name is used in an expression.
Measure
Check the variable names. Correct the spellling if necessary or define a
new variable.
2010 Fct. para value
Status The error is caused by the Easy-Plug function chr(). The argument, which
was assigned to the function, exceeds the admissible value range 0…255.
Measure
Change the argument (details see Easy-Plug manual)
2111 Invalid Date
Status Invalid date specification in a string.
Example: Function call DayOfYear(„31“,“6“,“2005“) would produce this error
message (because the date did not exist).
Measure
Correct the date specification.
See Easy-Plug Manual, topic section “Description of commands”, chapter
“Easy-Plug variables”.
3000/3003/3006/3012/3015 Com x Overrun
Status Receive error at the RS232 interface COMx (x = [1…5]).
Measure
Acknowledge by pressing the Online button.