1336 #YV no. incorr.
Status #YV field (variables data field) with the given no. not found.
Measure
Acknowledge by pressing the Online button.
Check the number of the #YV field.
Please read the notes in section Easy-Plug errors .
1390 Web width zero
Status The printer was set to printing several label rows (Easy Plug command
#ER, n > 1); but the label width was by fault set to zero (b = 0).
Measure
Correct the #ER command regarding the setting of parameter b.
Please read the notes in section Easy-Plug errors .
1391 Web > Width
Status The printer was set to printing several label rows (Easy Plug command
#ER, n > 1); but both or one of the parameters n and b are set in a way that
n * b (label row width * no. of rows) exceeds the material width.
Measure
Correct the #ER command regarding the setting of parameters n and b.
Please read the notes in section Easy-Plug errors .
1392 Job memory full
Status The error can have several causes.
Measure
Please read the notes in section Unspecific errors .
1393 Job struct creat
Status The error can have several causes.
Measure
Please read the notes in section Unspecific errors .
1394 Invalidation
Status General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors .