Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
23
1277 Wrong #!S..
Status Faulty Easy-Plug code. Faulty use of the immediate command "#!S..". The
specified parameter value exceeds the admissible value range (P, R).
Measure
Specify an admissible parameter value.
Please read the notes in section Easy-Plug errors .
1278 Wrong #!X..
Status Faulty Easy-Plug code. Faulty use of the immediate command "#!X..". The
specified parameter value exceeds the admissible value range (S, B, P).
Measure
Specify an admissible parameter value.
Please read the notes in section Easy-Plug errors .
1279 #!X wrong number
Status Faulty Easy-Plug code. Faulty use of the immediate command "#!X..". The
specified parameter value exceeds the admissible value range.
Measure
Specify an admissible parameter value.
Please read the notes in section Easy-Plug errors .
1282 Spooler FB > L
Status General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors .
1285 #!-comm. incorr.
Status Faulty Easy-Plug code. Faulty use of the immediate command "#!..!. The
specified letter is unknown.
Measure
Specify an admissible letter.
Please read the notes in section Easy-Plug errors .
1290 Label limit
Status Faulty Easy-Plug code. Value for x or y position exceeds the label limit.
Measure
Reduce the value for the x or y position.
Please read the notes in section Easy-Plug errors .
1291 Draw field
Status Faulty Easy-Plug code. Function call, drawing object, unsuccessful.
Please read the notes in section Easy-Plug errors .