Service manual
02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
17
1114 < Limit value
Status A sent Easy Plug command contains a value which exceeds the admissible
range at the bottom limit. The faulty value is replaced automatically by a
default value matching the limits.
Example: #YT109/-1/. The value –1 has been assigned to the parameter d.
Admissible for d are the values 0, 1, 2, 3. Therefore, -1 exceeds the value
range at the bottom limit.
Measure
Check the Easy Plug command on admissible values and correct them if
necessary.
Please read the notes in section Easy-Plug errors .
1115 > Limit value
Status A sent Easy Plug command contains a value which exceeds the admissible
range at the top limit. The faulty value is replaced automatically by a default
value matching the limits.
Example: #YT109/5/. The value 5 has been assigned to the parameter d.
Admissible for d are the values 0, 1, 2, 3. Therefore, 5 exceeds the value
range at the top limit.
Measure
Check the Easy Plug command on admissible values and correct them if
necessary.
Please read the notes in section Easy-Plug errors .
1120 Incorr. logo no.
Status Logo no. is invalid because it is outside of the address field. (self-
acknowledging)
Measure
Check whether the logo no. has been given as being smaller than 0 (zero)
or larger than 255.
1121 Logo exists
Status Logo already exists.
Measure
Change the designation of the logo; repeat saving.
1122 Creating logo
Status General software error
Measure
Please read the notes in section General software errors .
1123 Rename logo
Status General software error
Measure
Please read the notes in section General software errors .