Service manual

02/10 Rev. 5.04-03 USER + SERVICE MANUAL Status Reports
64-xx – 64-xx Dispenser – DPM – PEM – PM 3000 – ALX 92x – AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t
15
1087 OLV not active
Status OLV- specific Easy Plug commands have been used (#OLVI or #OLVD),
without having set the printer to OLV use at first.
Measure
Set the printer to OLV use.
See parameter INTERF. PARAM > COM2 PORT > Function Option.
1088 No realtimeclock
Status RTC-specific Easy Plug commands have been used (#YS or #YC), without
having a RTC installed.
Measure
Install a RTC.
For details refer to the Service Manual, topic section "General Service",
chapter "Assembling accessories" / "Option board".
1089 Seek Fkt. Error
Status General software error. An error occured while processing the function
„seek“ in the internal file system of the printer.
Measure
Confirm by pressing the Online button.
Please read the notes in section General software errors .
1090 Incomplete Job
Status The actual print job was not terminated by the #Q command. In other
words, after a start command #ER for a label format follows another #ER
command without the first format being terminated by #Q.
Measure
Confirm by pressing the Online button.
Terminate the print job with a #Q command.
1091 Wrong var field
Status An error occured while interpreting the text string of a variable data field.
The error could e.g. be caused by a #YT or a #YB command (Easy Plug).
Self-acknowledging error.
Measure
Check the text strings of variable data fields.
1092 Rename file
Status General software error
Measure
Please read the notes in section General software errors .
1093 Delete file
Status File cannot be deleted.
Measure
Check whether the file name is written correctly; check whether the file is
write-protected.