1008 Subcomm. incorr.
Status Unknown letter in a subcommand.
Measure
Check Easy Plug sequence.
1009 Param. tab inc.
Status General software error
Measure
Acknowledge by pressing the on-line button.
Please read the notes in section General software errors .
1010 #ER x #Q !
Status One or more illegal commands between #ER and #Q.
Measure
Check transmitted Easy Plug sequence.
Please read the notes in section Easy-Plug errors .
1011 #ER missing
Status One or more format commands without leading #ER (self-acknowledging)
Measure
None. The command is still carried out.
Please read the notes in section Easy-Plug errors .
1012 #IM x #Q !
Status One or more illegal commands between #IM and #Q.
Measure
Check Easy Plug sequence.
Please read the notes in section Easy-Plug errors .
1013 Comm. flag inc.
Status General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors .
1014 Uninit integer
Status General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors .
1015 Uninit float
Status General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section General software errors .