Instruction manual
Defining the Supply Setup Packet
Use the supply setup packet (B) to select supply type, ribbon, feed mode,
supply position, and cut position.
Syntax {I,B,sup ply_type,rib bon_on,feed_mode,sup ply_posn,
cut_posn,skip_in dex p}
B1. B Supply Setup Packet
B2. supply_type Supply Type. Options:
0 Black mark supply
1 Die Cut/edge aperture supply (default)
2 Continuous (non-indexed) supply
3 Center Aperture supply (9855/9860)
4 Reserved
5 Tag Edge Aperture (9855 RFID)
Note: You must use continuous supply in continuous mode. Do not use
continuous supply with extended backfeed or 94x5 emulation.
If your aperture supply has holes on the edge, use 1.
If your aperture supply has holes in the center, use 3.
If your aperture supply has holes on the edge and contains an
RFID antenna, use 5.
B3. ribbon_on Ribbon. Options:
0 Ribbon not installed
1 Ribbon installed (default)
2 High Energy Ribbon installed (9855/9860)
You must use a print speed of 2.5 IPS with the high energy ribbon. Serial
bar codes cannot be printed using the high energy ribbon. Settings for
ribbon and supply type must match the supplies loaded in the printer;
otherwise, an error occurs. To clear the error, turn off the printer and
change the configuration packet. Turn on the printer and resend the
packet.
B4. feed_mode Feed Mode. Options:
0 Continuous operation (default)
1 On-demand mode
Configuring the Printer 2-11