Instruction manual

This is the syntax to use when you create online configuration packets:
Syntax
{ Start of Header
I, Con fig u ra tion Header
1 - 8 op tional re cords
A, pa ram e ter 1...pa ram e ter 5 p Sys tem Setup
B, pa ram e ter 1...pa ram e ter 5 p Sup ply Setup
C, pa ram e ter 1...pa ram e ter 5 p Print Con trol
D, pa ram e ter 1...pa ram e ter 3 p Mon e tary For mat ting
E, pa ram e ter 1...pa ram e ter 9 p Con trol Char ac ters
F, pa ram e ter 1...pa ram e ter 5 p Com mu ni ca tion Set tings
G, pa ram e ter 1...pa ram e ter 4 p Backfeed Con trol
M, pa ram e ter 1...pa ram e ter 4 p Mem ory Con fig u ra tion
} End of Header
Syntax for single packet
{ Start of Header
I, Con fig u ra tion Header
A, pa ram e ter 1...pa ram e ter 5 Sys tem Setup
} End of Header
You can also add a configuration to RAM or specify units for supply, print,
margin, and cut positions. If you use the optional parameters with the I
packet, any online configuration packets following the split vertical bar ( p )
must specify distances using the selected units. However, the test labels
display the units in dots, even if you entered them in English or Metrics
units.
Syntax {header,ID#,action,device p }
1. header Constant I.
2. ID# ID. Use 0.
3. action Action. Options:
A Add configuration.
U Upload User Configuration.
4. device Storage Device. Use R (Volatile RAM).
2-6 Configuring the Printer