Instruction manual

730 A memory allocation error occurred during initialization.
732 RFID Hardware Error. A non-RFID printer received a format
containing an RFID Data Field.
RFID Errors
These errors occur when there is an RFID problem.
Error
Code
Description
740 Command, hardware, inventory, or memory allocation error.
There may be an RFID hardware or memory allocation error. The
printer does not recalibrate (feed a blank label) after any RFID
error.
741 RFID tag missing. Tag not found in RF Field. The RFID tag was
not found in the RF Field (area inside the printer where RFID tag
is programmed.) Check supply loading. If you changed the
supply or print position, make sure the RFID tag was not moved
out of the programmable range. The printer does not recalibrate
(feed a blank label) after any RFID error.
742 Tag erase failed. The RFID tag was found in the RF Field, but
could not be erased. Increase the number of write retries. If this
error occurs consecutively, increase or decrease the write power
setting. If the write power is set too low, you may affect the data
programmed in adjacent labels. The printer does not recalibrate
(feed a blank label) after any RFID error. For more information,
refer to your RFID Setup Guide & Supply Chart.
743 Program tag failed. The RFID tag was found in the RF Field, but
could not be programmed. Increase the number of write retries.
If this error occurs consecutively, increase or decrease the write
power setting by one. If the write power is set too low, you may
affect the data programmed in adjacent labels. The printer does
not recalibrate (feed a blank label) after any RFID error. For more
information, refer to your RFID Setup Guide & Supply Chart.
8-20 Diagnostics and Errors