Instruction manual
Machine Faults
These errors occur when there is a problem with the printer.
Error
Code
Description
703 The printer sensed a calibration of different-sized black marks.
Make sure the correct supply is loaded.
704 Printer has not sensed a supply mark within the specified number
of inches or out of supplies.
Check the
¨ supply tracking
¨ supply marks
¨ black mark sensor position
¨ supply roll for binding.
Press ESCAPE/CLEAR. If the error continues to appear, change
the supply.
710 Band out of data. Call Technical Support.
711 UART receiving communication error (framing, parity, etc.). Call
Technical Support.
712 Receiving failure or command overrun error. Call Technical
Support.
713 Receiving failure or illegal command. Call Technical Support.
714 Receiving failure or undefined command. Call Technical Support.
715 Invalid data length/data mismatch. The data in the RFID Data
Field has an incorrect data length or there is a data type mismatch
between the selected data type and the actual data entered. See
“Defining the RFID Data Field” in Chapter 3 for more information
on the data length and for selecting the appropriate data type for
the data being entered. This error also occurs if any of the
Expanded C1Gen2 fields is invalid. The printer does not
recalibrate (feed a blank label) after any RFID error.
Diagnostics and Errors 8-19