“~028" Identifies information to be appended. Reserved for future use. Only
include the field separator (decimal 028) in this field.
“Acs_Pwd~028" Access Password. This must be 8 ASCII Hex characters. No password is
assigned if this field is left blank. The data must end with the ASCII field
separator (decimal 028).
“Kill_Pwd~028" Kill Password. This must be 8 ASCII Hex characters. No password is
assigned if this field is left blank. The data must end with the ASCII field
separator (decimal 028).
“Lock_Code~028" Five-digit locking method for each field in this order:
EPC Data, User memory, Reserved, Access password, and Kill password.
Use 0 for the reserved field. Locking options:
0 No lock (default)
1 Permalock
2 Password lock
3 Permalock & password lock
Note: Use only one locking method per field. The printer is not capable
of unlocking a field. Depending on the locking method used for
each field, the EPC data may be programmable by sending the
access password with the batch data.
Example {F,2,A,R,E,400,400,"PERMLOCK" p
X,1,100,0 p }
{B,2,N,1 p
1,"313233343536373831323334~028" p
C,"ABCDEF~028" p
C,"~028" p
C,"73737373~028" p
C,"CAD01234~028" p
C,"11001" p }
The EPC data is 313233343536373831323334, the user memory data is
ABCDEF, the access password is 73737373, and the kill password is
CAD01234. Selects permalock (1) as the locking method for the EPC, user
memory, and kill field. Selects no lock (0) for the access password field.
The EPC, user memory, and kill fields are permanently readable/writable.
Printing 6-11