Instruction manual

Using Expanded EPC Gen2 RFID Data
With version 5.0 or greater software, we support Expanded C1Gen2 RFID
data, which is composed of five different fields:
¨ EPC Data (64 or 96-bits) ¨ Access Password
¨ User Memory ¨ Kill Password
¨ Lock Code
The printer also accepts EPC data following the guidelines in the
EPCglobalä Tag Data Standards Specification, which conforms to the EPCä
Radio-Frequency Identity Protocols Class 1 Generation 2 UHF RFID
Protocol for Communications at 860-960MHz Standards (RFID Air Interface
protocol). Refer to the EPC Specification to create valid EPC data.
Many different RFID supplies (tags) are available and the amount of
programmable user memory varies with the chip embedded in the tag.
Depending on your tag type, all memory fields may not be available. Refer
to the RFID Setup Guide & Supply Chart for details about the available user
memory for each chip.
Note: Incrementing an Expanded C1Gen2 RFID Data Field is not
supported.
Use the access password to control when new data can be written to a field.
The kill password sets a tag up to be inoperable. The lock code contains
the locking method.
6-8 Printing