Instruction manual
Option 64 (Program AFI Field for UHF RFID)
Use Option 64 to program the AFI memory in the EPC memory bank (field)
for UHF RFID tags. Unlike the AFI field for HF tags, currently, the AFI field
cannot be locked for UHF tags.
Note: Do not apply a lock to the EPC memory bank since the AFI memory
is part of the EPC memory bank. If the EPC memory bank is
locked, the AFI memory cannot be programmed (the printer errors).
For more information about using EPC data or locking fields, refer to the
Multi-Protocol Application Notes (available on our Web site).
Syntax R,64,field,"code",lock¦
R1. R Option Header.
R2. 64 Option 64.
R3. field Memory field to program. Use A (AFI).
R4. “code”
Byte code. This is an 8-bit (1 byte) character to program, enclosed within
quotation marks. Range: 0-255. Use the ASCII character or the tilde
followed by the equivalent three-character decimal value. For example, the
letter “A” can be entered as “A” or “~041”.
R5. lock Lock code. Use 0 (no lock).
Example X,5,16,0,0¦
R,64,A,"A",0¦
Programs the character “A” into the AFI memory field. The data is not
locked (0).
Example X,5,16,0,0¦
R,64,A,"~046",0¦
Programs the character “F” into the AFI memory field. The data is not
locked (0).
4-26 Defining Field Options