Instruction manual

Option 53 (Optional Settings for Aztec)
You can use Option 53 to set the error control level, enable ECI data,
enable a menu symbol, and add appended data to an Aztec bar code.
Note: Typically, these settings are not used. When using Option 53, the
printer may take longer to image the bar code and require more time
to print the format.
Syntax R,53,error_ctrl,ECI,menu_sym,str_append,"string"¦
R1. R Option Header.
R2. 53 Option 53.
R3. error_ctrl Error control level. Some damaged bar codes may still be scannable if the
error control level is high enough. Options:
0 Default level
1-99
101-104
201-232
300
R4. ECI Sets the ECI Data flag. The default is 0. Options:
0 Disable
1 Enable
R5. menu_sym Sets the Menu Symbol flag. The default is 0. Options:
0 Disable
1 Enable
R6. str_append Structured append information. Range: 1-26. The default is 1.
R7. “string” String to append. Range: 0-24. The default is “”. Must be enclosed in
quotation marks.
Example R,53,0,0,0,1,""¦
Uses option 53 to set the error control to 0, disables the ECI data and menu
symbol flags, and does not append any data to the bar code.
Defining Field Options 4-21