Instruction manual
42 Format as a price field
50 Define bar code densities
51 Define security and truncation of PDF417 bar codes
52 Define width or length of PDF417 bar codes
53 Define optional settings for Aztec bar codes
60 Define incrementing or decrementing field
61 Reimage fields
62 Do not scan/verify a particular bar code
64 Program the AFI Field for UHF RFID tags
R3. parameter(s)
Varies per option. See the following option descriptions.
Applying Options to the RFID Data Field
All the normal field options (copy, merge, pad, increment, etc.) can be
applied to the RFID Data Field. However, certain restrictions may apply.
¨ To copy, merge, pad, or increment data in the RFID Data Field, the
copied/merged/padded/incremented data must be in the same format
specified in the RFID Data Field. For example, to copy data into the
RFID Data Field using ASCII Hex, the field being copied must be in
ASCII Hex format; otherwise, unexpected results may occur.
¨ When incrementing the RFID Data Field, see the following table for an
explanation of how the field increments.
Data Type How the Field Increments
ASCII Hex 0 to F (0123456789ABCDEF), then back to 0
ASCII Binary 0 to 1 or 1 to 0
ASCII or Hex next position in 0 to 255 range
¨ If Option 60 (Increment Field) contains the character “D” to decrement, it
is ignored and the field is instead incremented by one.
¨ When incrementing the RFID Data Field, the only valid value to
increment is by one.
¨ Use caution when incrementing an RFID field if data is coming directly
from your host because the field must be incremented in ASCII Hex (or
other specified data type).
Defining Field Options 4-3