Instruction manual
Password Lock Example
{F,1,A,R,E,400,400,"PWDLOCK"¦
X,1,100,0¦} RFID Data Field
{B,1,N,1¦
1,"313233343536373831323334~028"¦ EPC Data
C,"ABCDEF ~028"¦ User Memory
C,"~028"¦ Reserved
C,"73737373~028"¦ Access Password
C,"CAD01234~028"¦ Kill Password
C,"22022"¦} Lock Method for each field
The EPC data is 313233343536373831323334, the user memory data is
ABCDEF, the access password is 73737373, and the kill password is
CAD01234. Selects password lock (2) as the locking method for the
EPC, user memory, access, and kill fields. To change the EPC, user
memory, or kill fields, the access password must be sent with the batch
data.
Both Lock Example
{F,1,A,R,E,400,400,"BOTHLOCK"¦
X,1,100,0¦} RFID Data Field
{B,1,N,1¦
1,"313233343536373831323334~028"¦ EPC Data
C,"ABCDEF ~028"¦ User Memory
C,"~028"¦ Reserved
C,"73737373~028"¦ Access Password
C,"CAD01234~028"¦ Kill Password
C,"33033"¦} Lock Method for each field
The EPC data is 313233343536373831323334, the user memory data is
ABCDEF, the access password is 73737373, and the kill password is
CAD01234. Selects permalock and password lock (3) as the locking
method for the EPC, user memory, access, and kill fields, which means
these fields are never rewritable. The EPC data can only be programmed
ONE time.
Defining the RFID Data Field 4-19