Instruction manual

2-6 Packet Reference Manual
A6. symbol_set Symbol Set. Options:
0 Internal (default)
1 ANSI
2 Code Page 437 (Latin U.S.)
3 Code Page 850 (Latin 1)
4 Code Page 1250 (Latin 2)
5 Code Page 1251 (Cyrillic)
6 Code Page 1252 (Latin 1)
7 Code Page 1253 (Greek)
8 Code Page 1254 (Turkish)
9 Code Page 1255 (Hebrew)
10 Code Page 1256 (Arabic)
11 Code Page 1257 (Baltic)
12 Code Page 1258 (Vietnamese)
13 DOS Code Page 852 (Latin 2)
14 DOS Code Page 855 (Russian)
15 DOS Code Page 857 (IBM Turkish)
16 DOS Code Page 860 (Portuguese)
19 Unicode
Note: The Standard, Reduced, Bold, OCRA and HR fonts only support the Internal
Symbol Set (0). The CG Triumvirate™ typefaces only support the ANSI and
DOS Code Page 437 and 850 Symbol Sets. The scalable font (font#50) does
not support Code Page 1256 (Arabic). Code pages 852-860 and 1250-1258
may only be used with downloaded TrueType® fonts or the scalable font.
Symbol set 19 requires a downloaded International TrueType font. TrueType
fonts are designed to be regionally specific; therefore, all code pages may not
be supported in a given font. See Appendix C, “Symbol Sets/ Code Pages
” for
more information.
Example {I,A,0,0,0,1,0 | }
Powers up the printer in the online mode, displays prompts in English, does not print a batch
separator, prints zeros with slashes through them, and uses the internal symbol set.
Defining the Supply Setup Packet
Use the supply setup packet (B) to select supply type, printhead energy, feed mode, and
supply position.
Syntax {I,B,supply_type,ph_energy,feed_mode,supply_posn | }
B1. B Supply Setup Packet
B2. supply_type Supply Type. Options:
0 Black mark supply
1 Die Cut/edge aperture supply (default)
2 Continuous (non-indexed) supply
Note: You must use continuous supply in continuous mode. You may need to adjust
the print contrast (in the Print Control packet) based on the supply type.
B3. ph_energy Printhead energy. Options:
0 Standard Supplies (default)
1 Special (fax paper)
2 High Energy (linerless and synthetic)
Note: We do not recommend printing serial bar codes with linerless supplies.
B4. feed_mode Feed Mode. Options:
0 Continuous operation (default)
1 On-demand mode (purchase optional)