Instruction manual

Diagnostics and Errors 8-7
Error Description
Code
261 Margin adjustment (position) must be -99 to 99 dots.
262 Speed adjustment must be 0 (default), 20 (2.0 ips), or 30 (3.0 ips).
263 Primary monetary symbol must be 0 (None), 1 (Dollar), 2 (Pound), 3 (Yen), 4
(Deutsche Mark), 5 (Franc), 6 (Peseta), 7 (Lira), 8 (Krona), 9 (Markka), 10 (Schilling),
11 (Rupee), 12 (Ruble), 13 (Won), 14 (Baht), 15 (Yuan), or 16 (Euro).
264 Secondary symbol selection must be 0 (none) or 1 (print secondary sign).
265 Monetary decimal places must be 0 to 3.
266 Character string length in the control characters packet must be 5 (MPCL control
characters) or 7 (ENQ/IMD command character).
267 Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3 (9600), 4 (19200), 5
(38400), 6 (57600), or 7 (115200). Resend the communication settings packet.
268 Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the communication
settings packet.
269 Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the communication settings
packet.
270 Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend the communication
settings packet.
271 Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or 3 (XON/XOFF).
Resend the communication settings packet.
272 Symbol set (code page) in the System Setup packet must be 0 (Internal), 1 (ANSI), 2
(DOS 437), 3 (DOS 850), 4 (1250- Latin 2), 5 (1251- Cyrillic), 6 (1252- Latin 1), 7
(1253- Greek), 8 (1254- Turkish), 9 (1255- Hebrew), 10 (1256- Arabic), 11 (1257-
Baltic), 12 (1258- Vietnamese), 13 (852- Latin 2), 14 (855- Russian), 15 (857- IBM
Turkish), 16 (860- DOS Portuguese), 17 (Wingdings), 18 (Macintosh), or 19 (Unicode).
282 RS232 Trailer string is too long. Use a maximum of 3 characters.
283 ENQ Trailer string is too long. Use a maximum of 3 characters.
284 The buffer type must be D (Downloadable Fonts), F (Format), I (Image), R (Receive),
T (Transmit), or V (Scalable Fonts).
285 The storage device type in the memory configuration packet must be F (flash) or R
(volatile RAM).
286 The buffer size is invalid.
287 The printhead width must be 0.
290 Action must be 0 (disable) or 1 (enable) for the backfeed control packet or the printer
is active.
291 Dispense position must be 0, 10 to 200 dots, or the printer is active.
292 Backfeed distance must be 0, 10 to 200 dots, or the printer is active. The backfeed
distance can not be greater than the dispense position.