User manual

Users Manual LOKPRINT™ II Location / Power Requirements
9
power. Because of the higher current draw of the LOKPRINT™ II, the printer /
Finishing Station or Cold Knife should be on a separate electrical service of 15A.
Refer to the Printer and Finishing Station or Cold Knife serial number plates for their
line requirements. Please check with your local electrical code and have the system
wired by a qualified electrician.
LOKPRINT™ II Main Line Protection
The LOKPRINT™ II main AC power switch also serves as a resettable circuit
breaker. The 115V machine incorporates a 20A breaker while the 230V machine
uses a 10A breaker.
LOKPRINT™ II Internal Fuse Configuration
Branch Circuit Protection
Both controllers and the feed motor drive circuit have a 5x 20mm fuse as per the
following chart.
Device Fuse
Designator
AVERY
DENNISON Part #
115 VAC &
230VAC
U1 F3 990754 1.0A 250V FA
5x20mm
U2 F4 990754 1.0A 250V FA
5x20mm
Web
Feed
Motor
F6 990915 1.6A 250V TL
5x20mm