User manual

Users Manual LOKPRINT™ II Product Description
15
(6) Web under temperature alarm.
(7) Oven over temperature alarm.
(8) Guard open.
The recommended room temperature for the system is 60°F (15.5°C) to 90°F
(32.2°C). If a cooling system is required it should not be pointed directly at the
system to create drafts that could affect the sublimation process.
LOKPRINT™ II Specification
Sublimation method: Non-contact
Narrow polyester web
Dye sublimation thermal transfer inks
Web speed: Speed – 5 IPS - (127mm/second)
Web Size: Min: 1.062" (27mm)
Max: 2.0" (50.8mm)
Feed length: No restrictions on the LOKPRINT™ II station
Cutting: No cutter included in LOKPRINT™ II station
Interface: AVERY DENNISON 636LKP (one sided)
AVERY DENNISON 676LKP (2 over 0, 1 over 1 and 2 over 1) thermal printers
Finishing method
interface:
SS Finisher (ultra sonic cutter with stacker)
Cold knife (cutter and stacker)
12” Rewind
Dimensions 13.5" (34.5cm) high x 26.5" (67.3cm) wide x 23.5" (59.7cm) deep
Weight 58 Lbs. (26.3Kg.) Shipping Weight = 81 Lbs. (36.7Kg.)
Electrical 115 volt system: 90-132 VAC 50-60Hz 20Amp 1 Phase.
230 volt system: 180-265 VAC 50-60Hz 10Amp 1 Phase.
Temperature
60°F (15.5°C) to 90°F (32.2°C)
Humidity 5% to 90% non-condensing
Patent pending