Service manual
09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
84
Start mode
AP5.4
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
Determines the interpretation of a start signal at the foot switch jack.
Edge (Default setting) The falling (low active) signal edge triggers the printing of ex-
actly one label.
Level low active Labels of a certain print job are being printed as long as the signal level is
low. When using a foot switch, labels are printed as long as somebody keeps
the foot switch pressed.
Start source
AP5.4
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
Choose a signal source for the start signal:
Foot switch Optional foot switch is used to generate the start signal.
Light barrier (Default setting) Photoelectric switch at the dispensing edge which detects
the taking off of the dispensed label.
¯ The setting "Light barrier" is unsuitable for product sensors! Product
sensors must be connected to the I/O board!
Calibration mode
AP5.4
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
¯ Is only effective with label material shorter than 40 mm!
If label material shorter than 40mm is used, the printer automatically initiali-
zes before printing. This measuring of the label material improves the impres-
sion accuracy. The initialization occurs in the following cases:
y After switching the printer on
y After opening and closing the printhead pressure lever.
¯ Advice: Start the material initialization manually before printing. This is
done by pressing the feed button in offline mode.
Selecting a material initialization procedure:
Automatic (Default) Material initialization is done automatically. Therefore, the label ma-
terial is fed forwards and backwards several times.
¯ There is a risk of the dispensing edge roller getting jammed by labels
sticking to it, which were dispensed by the forward/backward movement. If