Service manual

09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
80
Status output
AP4.4 AP5.4 AP7.t
¯ Only with an I/O board mounted.
This parameter defines different events, which activate the output signal
MACHINE STATUS.
Low ribbon warn The signal is activated, if the ribbon roll diameter is less than the limit.
P See parameter Foil end warning on page 60.
Print job ready The signal is activated, if the printer has finished image processing and is
ready to start printing.
The signal is not activated, if:
y the print job is done,
y the print job was stopped,
y the printer was switched to offline mode,
y the printer is in pause mode.
Status polarity
AP4.4 AP5.4 AP7.t
¯ Only with an I/O board mounted.
Switches the polarity of the MACHINE STATUS signal.
Level high active The output is high when it is active, otherwise low.
Level low active The output is low when it is active, otherwise high. (Default)
End print mode
AP4.4 AP5.4 AP7.t
¯ Only with an I/O board mounted.
Concerns the output signal PRINT_END at the I/O board signal interface.
Determines the signal response after printing of a label.
Mode0 inactve No print end signal.
Mode1 high level Low, if the print module is just printing a label, otherwise high.
The output is also deactivated (= low) as long as labels are fed with “Feed
Button” or
“Feed Signal”.
Mode2 low level High, if the print module is just printing a label, otherwise low.
The output is also deactivated (= high) as long as labels are fed with “Feed
Button” or “Feed Signal”.
Mode3 low pulse (Default setting) Low for 20 ms after printing and dispensing a label.
The output is also activated (= low) after a label is fed with “Feed Button” or
“Feed Signal”.
Mode4 high pulse High for 20 ms after printing and dispensing a label.
The output is also activated (= high) after a label is fed with “Feed Button” or
“Feed Signal”.